Series 2000 Stainless Steel
Follow the steps below to custom configure a sensor for your application.
Mount?
A.
Orientation
Internal
External
B.
Mount Type
NPT
1/4"
3/8"
1/2"
1/2" X 1/2" ADAPTER
3/4"
3/4" X 1/2" ADAPTER
1"
1" X 1/2" ADAPTER
1-1/4"
1-1/4" X 1/2" ADAPTER
1-1/2"
1-1/2" X 1/2"ADAPTER
2"
2"X 1/2" ADAPTER
Straight
12 SAE
16 SAE
20 SAE
24 SAE
Flange
3-5/8" OD x .13 thick, 6 hole
3-5/8" OD x .13 thick, 6 hole x 1/2" NPT adapter
2.75" OD x .125" thick, 5 hole
2.75" OD x .125" thick, 5 hole x 1/2" NPT adapter
3" 150# ANSI standard
3" 150# ANSI standard x 1/2" NPT adapter
Other
None
C.
Comments
Float?
Part#
Material
Dimensions
Max PSI
S.G.
Operating Temp
FL-03
316 SS
2.04" dia x 2.0" Sphere
750 psi
0.60
-40°F to 300°F
FL-09
Buna-N
1.88" dia x 1.8" Cylinder
150 psi
0.40
180°F water (-40 to 230°F oil)
FL-10
Buna-N
1.18" dia x 1.75" Cylinder
150 psi
0.50
180°F water (-40 to 230°F oil)
FL-59
316 SS
2.15" dia x 1.98" Cylinder
30 psi at 150°F
0.70
-40°F to 375°F
FL-54
316 SS
2.30" dia x 2.30" Sphere
750 psi
0.50
-40°F to 300°F
FL-17
316 SS
1.61" dia x 1.37" Cylinder
225 psi
0.60
-40°F to 300°F
*Interface floats come standard with specific gravity of .95.
In the space below describe which levels need to have an interface float:
Retainer?
Grip ring (standard)
Set screw collars are recommended for turbulent or rugged applications.
Set screw collar
Weld collar
Actuation Levels?
Level
Dimension
Reed Switch
(VA Rating/
Switch State)
L5
70VA N.O.
70VA N.C.
100VA N.O.
100VA N.C.
3VA SPDT
20VA SPDT
25VA SPDT
60VA SPDT
100VA SPDT
L4
70VA N.O.
70VA N.C.
100VA N.O.
100VA N.C.
3VA SPDT
20VA SPDT
25VA SPDT
60VA SPDT
100VA SPDT
L3
70VA N.O.
70VA N.C.
100VA N.O.
100VA N.C.
3VA SPDT
20VA SPDT
25VA SPDT
60VA SPDT
100VA SPDT
L2
70VA N.O.
70VA N.C.
100VA N.O.
100VA N.C.
3VA SPDT
20VA SPDT
25VA SPDT
60VA SPDT
100VA SPDT
L1
70VA N.O.
70VA N.C.
100VA N.O.
100VA N.C.
3VA SPDT
20VA SPDT
25VA SPDT
60VA SPDT
100VA SPDT
Maximum distance for level 1 is 142.0"
N.O. = Normally Open
N.C. = Normally Closed
SPDT = Single Pole Double Throw
Wiring Type?
(24.0" Standard Wire Length)
A.
Common or Separate?
Common
Separate
B.
Receptacles, Lead Wires, or Cable?
Receptacle
Lead wires
Cable
C.
If Receptacle, please select type
Amp
Brad Harrison
Deutsch
Harting
Hirschmann
Lumberg
Molex
Packard
Other:
Temperature Sensing Option?
Thermostat
Thermocouple
Thermistor
Accessories?
A.
Relays
Dual Level Control 120 Volt 10 Amp
Dual Level Control 230 Volt 10 Amp
Dual Level Control 24 Volt 10 Amp
Mechanical Power Transfer 120volt 15amp N.O.
Mechanical Power Transfer 120volt 15amp N.C.
Mechanical Power Transfer 120volt 15amp SPDT
Solid State 120volt 6amp N.O.
Solid State 120volt 6amp N.C.
Solid State 120volt 10amp N.O.
Solid State 120volt 10amp N.C.
(for pump control applications choose the Dual Level Control relay)
B.
Junction Boxes
Explosion proof
NEMA 4
Other
C.
Slosh guards
Yes
No
Indication or Alarms?
Visual Indication
Explain Application:
Audible Alarm
Contact Information
First Name
Last Name
Position
Company
Address
City
State
AL
AK
AZ
AR
CA
CO
CT
DC
DE
FL
GA
HI
ID
IL
IN
IA
KS
KY
LA
MA
MD
ME
MI
MN
MO
MS
MT
NE
NV
NH
NJ
NM
NY
NC
ND
OH
OK
OR
PA
RI
SC
SD
TN
TX
UT
VT
VA
WA
WV
WI
WY
Zip/Postal Code
Province
Country
United States
Afghanistan
Albania
Algeria
American Samoa
Andorra
Angola
Anguilla
Antarctica
Antigua And Barbuda
Argentina
Armenia
Aruba
Australia
Austria
Azerbaijan
Bahamas
Bahrain
Bangladesh
Barbados
Belarus
Belgium
Belize
Benin
Bermuda
Bhutan
Bolivia
Bosnia and Herzegowina
Botswana
Bouvet Island
Brazil
Bulgaria
Burkina Faso
Burma
Burundi
Cambodia
Cameroon
Canada
Cape Verde
Cayman Islands
Central African Republic
Chad
Chile
China
Christmas Island
Colombia
Comoros
Congo
Cook Islands
Costa Rica
Cote d'Ivoire
Croatia
Cyprus
Czech Republic
Denmark
Djibouti
Dominica
Dominican Republic
East Timor
Ecuador
Egypt
El Salvador
England
Equatorial Guinea
Eritrea
Espana
Estonia
Ethiopia
Faroe Islands
Fiji
Finland
France
French Guiana
French Polynesia
Gabon
Gambia
Georgia
Germany
Ghana
Gibraltar
Great Britain
Greece
Greenland
Grenada
Guadeloupe
Guam
Guatemala
Guinea
Guinea-Bissau
Guyana
Haiti
Honduras
Hong Kong
Hungary
Iceland
India
Indonesia
Ireland
Israel
Italy
Jamaica
Japan
Jordan
Kazakhstan
Kenya
Kiribati
Korea (South)
Korea, Republic of
Kuwait
Kyrgyzstan
Latvia
Lebanon
Lesotho
Liberia
Liechtenstein
Lithuania
Luxembourg
Macau
Macedonia
Madagascar
Malawi
Malaysia
Maldives
Mali
Malta
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte
Mexico
Moldova, Republic of
Monaco
Mongolia
Montserrat
Morocco
Mozambique
Myanmar
Namibia
Nauru
Nepal
Netherlands
Netherlands Antilles
New Caledonia
New Zealand
Nicaragua
Niger
Nigeria
Niue
Norfolk Island
Northern Ireland
Northern Mariana Islands
Norway
Oman
Pakistan
Palau
Panama
Papua New Guinea
Paraguay
Peru
Philippines
Pitcairn
Poland
Portugal
Puerto Rico
Qatar
Reunion
Romania
Russia
Russian Federation
Rwanda
Saint Lucia
Samoa
San Marino
Saudi Arabia
Scotland
Senegal
Seychelles
Sierra Leone
Singapore
Slovakia
Slovenia
Solomon Islands
Somalia
South Africa
South Korea
Spain
Sri Lanka
St. Helena
Suriname
Swaziland
Sweden
Switzerland
Taiwan
Tajikistan
Tanzania
Thailand
Togo
Tokelau
Tonga
Trinidad
Trinidad and Tobago
Tunisia
Turkey
Turkmenistan
Tuvalu
USA
Uganda
Ukraine
United Arab Emirates
United Kingdom
United States
Uruguay
Uzbekistan
Vanuatu
Venezuela
Viet Nam
Virgin Islands (British)
Virgin Islands (U.S.)
Wales
Western Sahara
Yemen
Zambia
Zimbabwe
Telephone
Fax
Web Site Address
Email
Need by Date
Quantity Desired
General Comments
Products
|
Industries Served
|
Typical Applications
|
FAQs
|
Contact Us
|
Site Map
|
Liquid Level Home
P: 860.621.7220
F: 860.620.0288
Toll Free: 800.789.2851
Email:
info@liquidlevel.com
Web site developed by
Innovative Internet Marketing Solutions